Every Friday we summarise the OT security incidents, actively exploited vulnerabilities and threat actor activity that matter for plant operators and machine builders in Germany, Austria and Switzerland. Each report rates the threat level, explains what it means for production and maintenance, and says what to do first.

Reports

Weekly situation reports

Max Gilg, OT cybersecurity expert from Rosenheim, and our team review every item against primary sources. Recommendations follow the SANS Five ICS Cybersecurity Critical Controls, for example secure remote access (CC4) and risk-based vulnerability management (CC5).

Threat level: Elevated

OT-Cyber Weekly Situation Report, all sectors, CW 46/2026

Period 06.11.2026 to 13.11.2026 · published 13.11.2026

In the reporting period (06.11. to 13.11.) the focus was on two topics: refrigeration systems and remote maintenance access. According to BleepingComputer (09.11.), France attributes the October attacks on Danfoss refrigeration controllers in around 700 targeted stores to a unit close to Iran's Revolutionary Guards. The later wave in November in six European countries has not been attributed. Our assessment: devices from these manufacturers are probably in use in DACH as well, so refrigeration equipment with remote maintenance belongs in the OT asset inventory.

The second construction site is remote access. On 10.11., MB connect line published two PHP vulnerabilities in the remote maintenance portal mbCONNECT24 via CERT@VDE (remote code execution without authentication, CVSS 3.1: 9.8 and 8.1). CISA lists a SonicWall SSL VPN vulnerability as actively exploited since 06.11. Siemens has no fix yet for the WinCC Graphics Designer. For OpenSSH on Linux systems with musl libc and without PAM, the fix is in OpenSSH 10.6p2. If you only manage one thing this week: patch remote maintenance portals and VPN gateways, and disconnect refrigeration controllers from the internet.

Recommendation for management: This week, order an inventory of all remote maintenance access, including access by refrigeration contractors and machine builders, and have the patch level confirmed to you by the end of the month. In our assessment, service provider access is currently the most likely way in.

Key items

  • MB connect line mbCONNECT24: remote code execution without authentication through bundled PHP (VDE-2026-128, CVSS 9.8) (MB connect line, coordinated by CERT@VDE)
  • Refrigeration attacks: France holds the IRGC-linked unit "Shahid Kaveh" responsible (BleepingComputer)
  • SonicWall SonicOS SSL VPN: CVE-2026-19868 actively exploited (CISA KEV) (CISA)
  • OpenSSH "SSHole": login without a valid password on Linux with musl libc without PAM (fixed in OpenSSH 10.6p2) (OpenSSH (oss-security) / SecurityWeek)
  • Siemens SIMATIC WinCC Graphics Designer: code execution through a crafted file, no fix yet (SSA-979641) (Siemens ProductCERT)

Full report as PDF German original

Threat level: High

OT-Cyber Weekly Situation Report, all sectors, CW 45/2026

Period 30.10.2026 to 06.11.2026 · published 06.11.2026

The threat level is high: attackers are actively exploiting OT-adjacent gateways and remote maintenance paths, in Germany with measurable damage. First review and restrict remote access for service providers, then patch the affected Zyxel switches and every internet-facing gateway.

Key items

  • Refrigeration systems in German supermarkets attacked, the path apparently led through the remote maintenance provider (Handelsblatt (dpa))
  • Zyxel GS1900: zero-day CVE-2026-107441, 996 switches in 48 countries compromised (BleepingComputer)
  • Stadtwerke Waldbröl (North Rhine-Westphalia) extorted, customer data stolen (Oberberg-Aktuell)

Full report as PDF German original

Daily updates and reports by sector are available in German: OT-Lagebild and OT-Lageberichte.

Frequently asked questions

What is the OT-Cyber weekly situation report?

A weekly summary of OT security incidents, vulnerabilities and threat actor activity relevant to operators and machine builders in Germany, Austria and Switzerland, with an overall threat level and concrete recommendations. It is published as a PDF every Friday, after the German report.

Who is it for?

OT and IT managers, production managers, maintenance teams and management in industry and critical infrastructure. Each report includes a short recommendation for management and actions mapped to the SANS Five ICS Cybersecurity Critical Controls.

Our production is down after a cyber attack. Who helps?

Call our OT incident response line, available 24/7. We help to contain the incident, keep or restore safe operation and plan the restart of the plant.

Is there a German version?

Yes. The German reports, also by sector (energy, food and beverage, machine building), are on our German report page; every English report links to its German original.

Emergency in your plant? Call 24/7: +49 8031 8603164 · Contact us